Skip to contents

Calculates WBGT for occupational heat stress assessment. Uses the standard formula: WBGT = 0.7Tnwb + 0.2Tg + 0.1Ta (outdoor) or WBGT = 0.7Tnwb + 0.3*Tg (indoor/shaded).

Usage

wbgt_simple(temp_c, rh, wind_speed = 0.5, solar_radiation = NULL)

Arguments

temp_c

Air temperature in Celsius

rh

Relative humidity as percentage (0-100)

wind_speed

Wind speed in m/s (default: 0.5 for still air)

solar_radiation

Solar radiation in W/m2 (NULL for indoor/shaded)

Value

WBGT in Celsius

References

Liljegren, J.C., et al. (2008). Modeling the Wet Bulb Globe Temperature Using Standard Meteorological Measurements. J. Occup. Environ. Hyg., 5(10), 645-655. Methods for Estimating Wet Bulb Globe Temperature

Examples

wbgt_simple(35, 70)
#> [1] 31.67735
wbgt_simple(35, 70, wind_speed = 2, solar_radiation = 800)
#> [1] 36.10711